Dean 1896 Natural Gas Safety Control 3.5" WC Model 7000 BMVR

SKU: 1896 Availability:
Out of Stock
(0)

null


Have a Question? +1 (866) 963-0907

Specifications:

Attribute Details
Nat Gas Safety, 3.5" Wc, Model 7000 Bmvr, Mfg#700-506
3/4" Fpt In X 3/4" Fpt Out, Includes 3/4" X 1/2" Reducer
Bushings, Millivolt Actuator, Requires Wire Lead
Thermopile, 36" # 51-1121 Or 60" # 51-1257
1/4" Cct Pilot Out, 300,000 Btu
For Lp Conversion Use # 51-1470
Bakers Pride Oven Following Models Made After 10/94
Y600, Y800, Ds-805, Gs-805, D-125, 101, 151, 201
251, 301, 351, 3151, 401, 451, 4151, Fc-(516,616,816)
Cecilware Fryer Fmp-30, Fmp-40, Fmp-65, Fmp-403, Fms-30,
Fms-40, Fms-65.
Frymaster Fryer Models Made Before Feb. 1993 Gf14, Gf40,
J1C, Jcfx, J3Fc, J65X, Mj15, Mj35, Mj235, Mjcf.
Imperial Fryer Series If, Ihr, Ir.
Keating Fryer Gas Counter Units And Miraclean Griddles.

Dimensions:

  • Weight: 2.4 lbs
  • Length: 5.7 in
  • Height: 3.5 in
  • Width: 4.5 in

More Information:

Step1: Turn off gas supply and power to the fryer before starting work.

Step2: Allow equipment to cool completely for better handling.

Step3: Remove access panel to reach gas control assembly.

Step4: Disconnect inlet/outlet gas lines and pilot tubing.

Step5: Remove faulty safety control valve from mounting position.

Step6: Install new valve ensuring correct orientation.

Step7: Reconnect all lines tightly and check for leaks with approved solution.

Step8: Restore gas and test burner ignition for proper safety shutdown response.

Customer Reviews