Tri-Star 300188 Fryer Natural Gas Safety Control Valve 7000 BMVR 3.5" WC

SKU: 300188 Availability:
Out of Stock
(0)

null


Have a Question? +1 (866) 963-0907

Specifications:

Attribute Details
Nat Gas Safety, 3.5" Wc, Model 7000 Bmvr, Mfg#700-506
3/4" Fpt In X 3/4" Fpt Out, Includes 3/4" X 1/2" Reducer
Bushings, Millivolt Actuator, Requires Wire Lead
Thermopile, 36" # 51-1121 Or 60" # 51-1257
1/4" Cct Pilot Out, 300,000 Btu
For Lp Conversion Use # 51-1470
Bakers Pride Oven Following Models Made After 10/94
Y600, Y800, Ds-805, Gs-805, D-125, 101, 151, 201
251, 301, 351, 3151, 401, 451, 4151, Fc-(516,616,816)
Cecilware Fryer Fmp-30, Fmp-40, Fmp-65, Fmp-403, Fms-30,
Fms-40, Fms-65.
Frymaster Fryer Models Made Before Feb. 1993 Gf14, Gf40,
J1C, Jcfx, J3Fc, J65X, Mj15, Mj35, Mj235, Mjcf.
Imperial Fryer Series If, Ihr, Ir.
Keating Fryer Gas Counter Units And Miraclean Griddles.

Dimensions:

  • Weight: 2.4 lbs
  • Length: 5.7 in
  • Height: 3.5 in
  • Width: 4.5 in

More Information:

Step1: Turn off gas fryer supply and disconnect power before servicing unit; ensure ventilation; verify compatibility.

Step2: Remove old valve and clean mounting area; inspect fittings and gas line.

Step3: Install new valve, align inlet/outlet, tighten fittings with proper sealant tape using approved method.

Step4: Reconnect lines, restore gas slowly, check for leaks with soap solution.

Step5: Test ignition and burner operation; ensure safety shutoff works and shutdown safety test.

Customer Reviews