Frymaster FM8072428 Natural Gas Safety Control 3.5" WC Model 7000 BMVR

SKU: FM8072428 Availability:
Out of Stock
(0)

null


Have a Question? +1 (866) 963-0907

Specifications:

Attribute Details
Nat Gas Safety, 3.5" Wc, Model 7000 Bmvr, Mfg#700-506
3/4" Fpt In X 3/4" Fpt Out, Includes 3/4" X 1/2" Reducer
Bushings, Millivolt Actuator, Requires Wire Lead
Thermopile, 36" # 51-1121 Or 60" # 51-1257
1/4" Cct Pilot Out, 300,000 Btu
For Lp Conversion Use # 51-1470
Bakers Pride Oven Following Models Made After 10/94
Y600, Y800, Ds-805, Gs-805, D-125, 101, 151, 201
251, 301, 351, 3151, 401, 451, 4151, Fc-(516,616,816)
Cecilware Fryer Fmp-30, Fmp-40, Fmp-65, Fmp-403, Fms-30,
Fms-40, Fms-65.
Frymaster Fryer Models Made Before Feb. 1993 Gf14, Gf40,
J1C, Jcfx, J3Fc, J65X, Mj15, Mj35, Mj235, Mjcf.
Imperial Fryer Series If, Ihr, Ir.
Keating Fryer Gas Counter Units And Miraclean Griddles.

Dimensions:

  • Weight: 2.4 lbs
  • Length: 5.7 in
  • Height: 3.5 in
  • Width: 4.5 in

More Information:

Step1: Turn off gas supply and disconnect electrical power to fryer system.

Step2: Remove old safety control and label all wiring connections carefully.

Step3: Mount the unit securely on designated bracket or panel.

Step4: Reconnect gas and electrical lines as per manufacturer schematic.

Step5: Check all fittings for leaks using approved leak detection solution.

Step6: Restore power and test ignition and safety shutdown operations carefully.

Customer Reviews